Key Features:
- Wide frequency range.
- High quality.
- Low phase noise signal.
- High dynamic range.
- Precise power output
- Compatible with the SAV82406 series frequency extender to extend output frequency up to 500 GHz
- Wide frequency range: 3Hz - 50GHz
- Optional Extenders extends frequency up to 325 GHz.
- Maximum analysis bandwidth up to 200MHz.
- Comprehensive spectrum analysis.
- FFT sweep supported.
- Multi-domain correlation analysis and signal playback.
- Support analogue and digital signal output interface.
- 2CH Oscilloscopes max to 200MHz
- 1GSa/s Real Time sample rate
- IP 51 protection
- 6000 counts DMM,AC/DC voltage, AC/DC current, resistance, break, capacitance, and diode function.
- FFT/Waveform math/Pass&Fail test/X-Y mode/ 20+ auto measurement
- 1000 frame recorder
- Flexible data output, word, excel, bmp, jpg
- 2CH oscilloscope
- 1M memory depth
- 1GSa/s sample rate
- 200MHz/100MHz/60MHz bandwidth available
- 16CH logic analyzer, sample rate 500MSa/s
- More than 30 kinds automotive measurement, FFT included
- Trigger functions: Video, Edge, Pulse Width, Slope, Overtime, Alter etc.
- 4CH Oscilloscopes
- 250MHz / 200MHz / 100MHz / 80MHz bandwidth available
- 7’’ large color display, WVGA (800x480)
- 30+ kinds Automotive measurement, FFT included
- 1CH 25MHz Arbitrary/Function Waveform Generator.
- 2CH Oscilloscopes
- 40K Memory Depth
- 200MHz / 100MHz / 70MHz bandwidth available
- 1CH 25MHz Arbitrary/Function Waveform Generator, max 75MHz for sin wave
- Frequency coverage from 100 kHz to 3 GHz
- Excellent specifications
- AM,FM,PM,Pulse modulation function
- ASK, FSK, PSK modulation function
- Small size, low weight
- Friendly UI, easy to use
- Frequency range: 9kHz - 7.5GHz
- DANL <-150dBm, <-161dBm typ
- Max 3GHz tracking source and CW source
- Audio analysis
- Standard preamplifier/waterfall function/Limit line function
- SCPI supported
Digital storage, mixed signal and sampling oscilloscopes solve the toughest measurement challenges
When your AC power system has a problem you need to find it without delay; Fluke’s three-phase power meters will quickly provide the answers you need to get things running smoothly. These meters can be used for troubleshooting to find the answers now; or as benchmarking tools to discover the trend of your power quality over time. Fluke power quality meters can provide all the answers you need to effectively troubleshoot power quality issues rapidly.
Key features
- Versatile, three-phase Fluke Connect-compatible power logger for conducting basic energy and power quality studies
- Automatically captures and logs voltage, current, power, harmonics and associated power quality values.
- Provides the highest safety rating in the industry: 600 V CAT IV/1000 V CAT III rated for use at the service entrance and downstream
- Automatically logs all measured values and stores more than 20 separate logging sessions
- High performance supplies ideal for benchtop and automated testing
- From basic benchtop applications to high speed systems, these medium-power supplies simplify testing and enhance measurement accuracy.
- Save space and increase flexibility with modular multiple-output and compact single-output supplies
- Simplify cabling with built-in measurements
- Streamline tasks with front panel control and advanced programmable features
- Ensure DUT safety with protection features
- 20 Hz to 300 kHz/500 kHz/1 MHz, with 4-digit resolution in any range
- 0.05% basic accuracy with superior measurement repeatability at low and high impedance
- 100 uV to 2 Vrms, 1 uA to 20 mA variable test signal
- DC bias 1.5/2 V
- Auto-level control
- DC resistance
- 201 points list sweep
- Versatile PC connectivity (LAN, USB, and GPIB)
- Frequency Upgradability
- 0.02 % basic accuracy, 1 μΩ max. resolution, 300 mA max. measurable current
- Measure from 0.000 mΩ (testing current 300 mA) to 3.5 MΩ
- Probe for guard jack use and increased measurement current yield an instrument that’s more resistant to noise
- Optional LED COMPARATOR ATTACHMENT and high-volume judgment tones combine to ensure PASS/FAIL judgments are communicated reliably in the noisy environment of the production floor
- EXT I/O interface with NPN/PNP support can accommodate a variety of automated production lines (-01 model)
- Three frequency options: 1 MHz to 500 MHz/1 GHz/3 GHz, upgradable
- ±0.65% basic accuracy and 120 mΩ to 52 kΩ impedance range (10% measurement accuracy range)
- Measurement parameters: |Z|, |Y|, θ, R, X, G, B, L, C, D, Q, |Γ|, Γx, Γy, θΓ, Vac, Iac, Vdc1, Idc1 (1. Option 001 is required)
- Built-in DC bias (Option 001): 0 V to ±40 V, 0 A to ±100 mA
- Improve power measurements with touch-driven dynamic views
- Measure voltage, current and power on 4 channels: DC, 1-phase AC or 3-phase AC
- Make more accurate power measurements: 0.05% at 50/60 Hz
- Measure current directly: internal shunts to 50 Arms, or with external probes or transducers
- Address multiple test scenarios with isolated inputs
- 1 GHz to 6 GHz, DSO or MSO models
- See more signal detail with 450,000 wfms/s update rate
- Isolate signals in seconds with exclusive Zone Touch Triggering
- Operate hands-free with multi-language voice control
- Get more functionality with optional integrated digital channels, serial protocol analysis, dual-channel WaveGen and 10-digit counter + 3-digit voltmeter
- Protect your investment with full upgradability; add options and bandwidth at any time
- Continuous testing of insulation (500/1000 V) and withstand voltage (100 VA transformer capacity)
- Full remote operation when used in combination with the Safety Test Data Management Software 9267
- Save up to 8 test settings each for the withstanding and insulation testing modes
- Precise test voltage without power voltage dependency is generated using the PWM method
- Continuous testing of insulation (500/1000 V) and withstand voltage (500 VA transformer capacity)
- Testing voltage: 0 to 2.5 kV / 0 to 5.0 kV AC, 2 range configuration 500 VA (30 minutes rated)
- Insulation to withstand series test or withstand to insulation series test at auto mode, or individual test at manual mode
- Save up to 10 test settings each for the withstanding and insulation testing modes
- External I/O, RS-232C interface, Status output (relay contacts)
© 2000-2017 TM TECHNOLOGY. All rights reserved.
Desgin by vntsc.vn
175 patek philippe replica harga jam tangan rolex kw super fake watches can you sell replica watches on gumtree how to remove tag heuer strap bellross replica uk used omega speedmaster reduced steve mcqueen rolex daytona replica watch breitling navitimer 01 limited edition rolex oysterdate precision fake replica watches harga rolex daytona 1992 tag heuer battery life replica watch first copy watches in thane breitling smartwatch b55 replica watches